<![CDATA[Deange Industry Co., Ltd.]]> http://http://www.deange.com.tw Thu, 22 Feb 2024 16:08:39 +0800 3600 <![CDATA[General Thermocouple General Thermocouple (KB-600 / KN-601 / KN-602 / KN-603 / KN-690)(2019/Jul/24 13:30:02)]]> http://http://www.deange.com.tw/02-general_thermocouple.html Thermocouple size and style are available as per specific demand of customer.

(2019/Jul/24 13:30:02)]]>
Wed, 24 Jul 2019 13:30:02 +0800
<![CDATA[General Thermocouple General Thermocouple (KN-610 ~ KN-680)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/03-general_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Flange Thermocouple Flange Thermocouple (KD-810 / KN-820 / KN-830 / KT-850)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/04-flange_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (WTF-120 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/05-wires_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (WS-130 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/09-wires_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (WE-110 / WE-111 / WE-112PT)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/10-wires_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[Wires Thermocouple Mineral Insulated Thermocouple with Pot Seal and Spring (WE-252)(2024/Feb/23 13:41:50)]]> http://http://www.deange.com.tw/Mineral_Insulated_Thermocouple_WE-252.html ● Mineral Insulated Thermocouple with Pot Seal and Spring
● Probe can be bended
● Ideal for Very Long Probes
● Available in Very Small Diameters
● Wire type

 

(2024/Feb/23 13:41:50)]]>
Fri, 23 Feb 2024 13:41:50 +0800
<![CDATA[Wires Thermocouple Mineral Insulated Thermocouple (WI)(2024/Mar/8 10:14:49)]]> http://http://www.deange.com.tw/WI.html Fri, 8 Mar 2024 10:14:49 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (GF-250 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/07-wires_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (WE-230 / WE-231)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/15-wires_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (SFT-205 / SFT-206 / SFT-208)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/16-wires_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Wires Thermocouple Extension Wires Thermocouples (AK-106 / WE-250 Series)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/17-wires_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[Wires Thermocouple Hose Clamp Thermocouple (WO)(2024/Mar/18 14:24:27)]]> http://http://www.deange.com.tw/WO.html Hose clamp thermocouples are an easy way to measuring pipe and cylinder temperatures.

(2024/Mar/18 14:24:27)]]>
Mon, 18 Mar 2024 14:24:27 +0800
<![CDATA[Digital Thermometer and Temperature Surface Probe Series Digital Thermometer (305 307)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/06-digital_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Digital Thermometer and Temperature Surface Probe Series Thermometer / General Probes / Surface Probes / Moving Surface Probes (DE-100 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/11-digital_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Digital Thermometer and Temperature Surface Probe Series General Probes / Surface Probes / Moving Surface Probes (DE-105 / DE-300 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/12-digital_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Digital Thermometer and Temperature Surface Probe Series General Probes / Surface Probes / Moving Surface Probes (DE-305 / DE-305A / DE-305B / DE-306 / DE-307 / DE-308 / DE-308A / DE-311)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/13-digital_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[Digital Thermometer and Temperature Surface Probe Series Thermocouple Connectors and Thermocouple (DE-200 / DE-201 / DE-210 / DE-220)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/14-digital_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[General Thermocouple - A General Thermocouple (KS-500 Series)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/08-general_thermocouple.html Thu, 30 Dec 2010 16:50:17 +0800 <![CDATA[General Thermocouple - A General Thermocouple (KF-530 / KBS-540 Series)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/18-general_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[General Thermocouple - A General Thermocouple (TL-550 / TL-560 / TL-570)(2010/Dec/30 16:50:18)]]> http://http://www.deange.com.tw/19-general_thermocouple.html Thu, 30 Dec 2010 16:50:18 +0800 <![CDATA[Hirschmann Connector Hirschmann Connector (TB-6 Series) (TB-6/ TB-6A/ TB-6B)(2017/Mar/30 11:10:47)]]> http://http://www.deange.com.tw/TB-6-Series.html Products can be customized with specs.
(2017/Mar/30 11:10:47)]]>
Thu, 30 Mar 2017 11:10:47 +0800
<![CDATA[Hirschmann Connector Hirschmann Connector (TB-8 Series) (TB-8/ TB-8A/ TB-8B)(2017/Mar/30 11:10:03)]]> http://http://www.deange.com.tw/TB-8-Series.html Products can be customized with specs.
(2017/Mar/30 11:10:03)]]>
Thu, 30 Mar 2017 11:10:03 +0800
<![CDATA[Thermocouple Tolerance Thermocouple Tolerance (Thermocouple Tolerance - 01)(2010/Dec/30 16:50:17)]]> http://http://www.deange.com.tw/01-thermocouple_tolerance.html
(2) The measurement of tolerance is based on setting the cold junction at 0°C.

(3) The tolerance, either expressed in C or %, is based on the larger value of the two.(2010/Dec/30 16:50:17)]]>
Thu, 30 Dec 2010 16:50:17 +0800
<![CDATA[Thermocouple Wires Fiberglass Wire ()(2017/Mar/31 16:46:54)]]> http://http://www.deange.com.tw/Fiberglass-Wire.html Features

Fiberglass braded single conductor and duplex insulation.
Good abrasion ,fair abrasion resistance and chemical resistance.
Color code: ANSI, IEC, JIS.
Addition abrasion resistance: with stainless wire or Tinned Cooper wire overbraids.


 

Performance Capabilities

Continuous temperature service: 900°F ( 482°C ).
Single Exposure: 1000°F ( 537°C )

Applicable Range

Steel and aluminum plants
Heat treating.
Foundries.

(2017/Mar/31 16:46:54)]]>
Fri, 31 Mar 2017 16:46:54 +0800
<![CDATA[Thermocouple Wires Silicon Wire ()(2017/Mar/31 16:12:26)]]> http://http://www.deange.com.tw/Silicon-Wire.html Features

Teflon FEP single conductor and Silicon Robber duplex insulation

Excellent moisture and good chemical resistance

Color code: ANSI, IEC, JIS

Addition abrasion resistance: with stainless wire or Tinned Cooper wire overbraids 

Performance Capabilities
Continuous temperature service: 356°F ( 180°C )


 

(2017/Mar/31 16:12:26)]]>
Fri, 31 Mar 2017 16:12:26 +0800
<![CDATA[Thermocouple Wires FEP Wire / Teflon Wire ()(2017/Mar/31 16:14:10)]]> http://http://www.deange.com.tw/FEP-Wire.html Features

FEP single conductor and duplex insulation

Color code: you can select ANSI, IEC, JIS

Addition abrasion resistance: with Stainless wire or Tinned Cooper wire overbraids
 
 
 

Performance Capabilities

Continuous temperature service: -90°F ~ 400°F ( -67°C ~ 204°C )

Single Exposure: 482°F ( 250°C )

Excellent moisture and good chemical resistance 

Applicable Range

Aerospace

Industrial equipment testing

Glass manufacture

(2017/Mar/31 16:14:10)]]>
Fri, 31 Mar 2017 16:14:10 +0800
<![CDATA[Thermocouple Wires PVC Wire ()(2017/Mar/31 16:47:16)]]> http://http://www.deange.com.tw/PVC-Wire.html Features

˙PVC single conductor and duplex insulation .

˙Color code: You can select ANSI, IEC, JIS.

 ˙Addition abrasion resistance: with stainless wire or Tinned Cooper wire overbraids.




Performance Capabilities

˙Continuous temperature service: 220°F ( 105°C ).

˙Excellent moisture and good chemical resistance.

Applicable Range

˙Laboratories.

˙Industrial Equipment.

˙Hydrocarbon Processing plants.

(2017/Mar/31 16:47:16)]]>
Fri, 31 Mar 2017 16:47:16 +0800
<![CDATA[Thermocouple Wires PFA Wire ()(2017/Mar/31 14:11:38)]]> http://http://www.deange.com.tw/PFA-Wire.html


Features

PFA single conductor and duplex insulation

Color code: you can select ANSI, IEC, JIS

Addition abrasion resistance: with Stainless wire or Tinned Cooper wire overbraids

 

Performance Capabilities

Continuous temperature service: -90°F ~ 500°F ( -67°C ~ 260°C )

Single Exposure: 550°F ( 288°C )

Excellent moisture ,good chemical resistance and good abrasion resistance.

 

Applicable Range

Food processing facilities

Petrochemical plants

(2017/Mar/31 14:11:38)]]>
Fri, 31 Mar 2017 14:11:38 +0800
<![CDATA[Magnet Surface Probe Magnet Surface Probe (DE-106)(2024/Mar/18 14:36:14)]]> http://http://www.deange.com.tw/DE-106.html Magnet Surface Probe which can be attached to a magnetic metal to measure temperature.

 

 

(2024/Mar/18 14:36:14)]]>
Mon, 18 Mar 2024 14:36:14 +0800